Next Article in Journal
Crystal Structure and Thermoelectric Properties of Lightly Substituted Higher Manganese Silicides
Next Article in Special Issue
Simultaneous Evaluation of Creep Deformation and Recovery of Bulk-Fill Dental Composites Immersed in Food-Simulating Liquids
Previous Article in Journal
Degradation of Glaukonite Sandstone as a Result of Alkali-Silica Reactions in Cement Mortar
 
 
Font Type:
Arial Georgia Verdana
Font Size:
Aa Aa Aa
Line Spacing:
Column Width:
Background:
Article

Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Maxillofacial Silicone Elastomer

1
Loughborough Design School, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
2
Materials, Loughborough University, Loughborough, Leicestershire LE11 3TU, UK
*
Author to whom correspondence should be addressed.
Materials 2018, 11(6), 925; https://doi.org/10.3390/ma11060925
Submission received: 22 April 2018 / Revised: 25 May 2018 / Accepted: 25 May 2018 / Published: 30 May 2018
(This article belongs to the Collection Dental Biomaterials)

Abstract

:
The objective of this study was to determine the effect of plant based antimicrobial solutions specifically tea tree and Manuka oil on facial silicone elastomers. The purpose of this in vitro study was to evaluate the effect of disinfection with plant extract solution on mechanical properties and morphology on the silicone elastomer. Test specimens were subjected to disinfection using tea tree oil, Manuka oil and the staphylococcus epidermidis bacteria. Furthermore, a procedure duration was used in the disinfection process to simulate up to one year of usage. Over 500 test specimens were fabricated for all tests performed namely hardness, elongation, tensile, tear strength tests, visual inspection and lastly surface characterization using SEM. A repeated measures ANOVA revealed that hardness and elongation at break varied significantly over the time period, whereas this was not observed in the tear and tensile strength parameters of the test samples.

1. Introduction

Maxillofacial prostheses are usually fabricated to mask facial defects or deformities in patients, especially when surgery is not feasible. These defects or deformities are usually caused by cancer, traumatic accidents or congenital diseases and may affect speech, quality of speech, quality of life, psychology and social behavior. Deterioration of the prostheses is usually caused by environmental exposure namely ultraviolet (UV) light, air pollution and changes in humidity and temperature; and by handling, cleaning and removal of the prosthesis [1,2,3,4,5,6,7]. Research shows that these prostheses generally last 13 to 28 months [8,9,10].
Some desirable mechanical properties of maxillofacial prostheses are hardness; tensile strength, tear strength, elongation and many others. The hardness of maxillofacial material is a measure of its flexibility and should be comparable to that of the anatomic facial tissue [11,12]. Tensile strength is important in order to express overall strength of a material while hardness indicates the strength of a materials surface [11]. Elongation is a measure of flexibility and an indicator of the overall flexibility of a prostheses material with facial prostheses elastomer to rupture during use and maintenance [11]. Hence, it accommodates facial movement [12,13,14].

1.1. Degradation by Environment

The effect of weather on polymeric materials has strong dependence on geographic location, season, time of day, cloud cover and exposure orientation, since the critical weather factors vary with these conditions [15]. Environmental characteristics that cause degradation are sunlight, temperature, moisture, wind, dust and pollutants [15,16]. Weathering of polymers can induce changes in physical and chemical characteristics that result in significant modifications to their appearance, mechanical properties and thermal properties [15,16]. Polymer deterioration due to weathering is a result of a photo-oxidative attack, namely a combined action of oxygen and sunlight on a material’s chemical structure [16]. The photo-oxidative degradation causes an initial formation of free radicals; reaction of free radicals with oxygen, production of polymer oxy- and peroxy-radicals and secondary polymer radicals resulting in chain scission. Finally, a reaction of different free radicals with each other results in crosslinking [15] as stated elsewhere. The changes in physical properties affect the polymer’s structural network, namely the density, which causes an increase in crosslinking due to the formation of bonds between the existing monomers or between the chains.

1.2. Degradation by Cleaning/Handling

The prostheses can be exposed to mucosa, moist air and skin secretions (such as sweat, sebum and other products secreted by the skin), subsequently leading to a multilayer biofilm formation [9,17,18]. Biofilms are a structured community of cells enclosed in a self-produced polymeric matrix adherent to an inert or living surface [19]. Contamination of the prostheses’ surface can harbor microorganisms within its pores if not removed by cleaning [9,20]. For facial prostheses, it is unknown what percentage of failure is related to microorganisms, but adhesion of microorganisms to and formation of biofilms on surfaces of prostheses are well known causes for infections of medical devices [21]. Problems associated with microbial colonization of these prostheses are black stains on the prostheses surface, offensive odors and tissue infections [9].
Chronic infections by biofilms are of interest because of resistance of microorganisms present in the biofilm to antibiotics. Furthermore, the biofilm architecture, i.e., the layer on the surface of a prosthesis in which the cells are embedded in extracellular polysaccharide matrix, results in poor penetration of antibiotics through that layer [22]. Furthermore, nutritional support either extrinsically or intrinsically from within the prostheses will sustain further growth of these micro-organisms [17]. Disinfection of elastomers could alter their surface characteristics and the bulk of the material due to the extraction of some compounds from the matrix to disinfection solutions or the water as indicated in many studies [23,24]. Current cleaning methods for facial prostheses require patients to clean their prostheses meticulously. These cleaning methods include: Using a cotton bud soaked with mild soapy solution [17]; using a soft nylon bristled toothbrush and a mild detergent soap [20,25]; rinsing in tap water, pat dried with a towel and stored in a container away from direct light or heat or exposed to cigarette smoke [25]. Cleansing, care and storage conditions post-fabrication make the prostheses vulnerable to bacterial and fungal growth. Furthermore, surface topography (i.e., the roughness, surface irregularities, etc.), the hydrophobicity and chemistry all have an influence on the attachment of microorganisms to a surface. Neutral soap; sodium hypochlorite 1%; cleansing tablets; and chlorhexidine are some of the most commonly used cleansing agents for the facial silicone elastomer [7,26].
Furthermore, a study to elucidate the degree of satisfaction after maxillofacial prosthetic rehabilitation revealed that clinical efforts to ensure all patients were cognizant of the care of their prostheses [27]. Nevertheless, there was a misunderstanding relating to lack of soap and water usage; usage of inappropriate solvents; and infrequent cleansing that hastens the deterioration of prosthetic polymers, especially the periphery of the prostheses to the importance of keeping the prostheses meticulously clean [27].
Hence, it is essential to concentrate on the efficacy of the differing cleaning methods and materials to help establish suitable cleaning methods and or agents not only for peri-implant tissues but also for the maxillofacial prosthesis. Research has shown that frequent exposure to chemical disinfection may interfere with the properties of the silicone [23,28,29,30,31], hence it is essential to find alternative methods of disinfection. Furthermore, increased resistance of bacteria to antibiotics, adverse effects such as toxicity, allergenic and even mutagenic effects of some antibacterial agents currently used in dentistry and financial constraints [32] make it vital to explore other options of disinfection. Natural phytochemicals from phytotherapy is one possible option worth exploring as has been shown to be safe, effective and economical [32].
Natural antimicrobials are obtained from different sources, namely plants, animals, bacteria, algae and fungi [33]. Usage of broad spectrum antibiotics increases the apparent resistance to almost all commercially available antimicrobial drugs [34]. Antimicrobial compounds from plants serve as a defence mechanism against predation by microorganisms, insects, and herbivores either through their odors, or flavor [35]. The antimicrobial phytochemicals can be divided into several categories namely phenolics; terpenoids; alkaloids; lectins and polypeptides and polyacetylenes [35].
Antimicrobials utilized in this study (tea tree and Manuka oil) were chosen based on documented and/or anecdotal antimicrobial effects. Furthermore, a thorough search revealed that these oils had not previously been used as a cleanser for maxillofacial prostheses.
Tea tree oil is incorporated as the principal or natural preservative in many pharmaceutical and cosmetic products intended for external use [36]. It is derived from the Australian native plant Melaleuca alternifolia [37,38] and produced by steam distillation of its leaves and terminal branches [37,39]. Once condensed, the clear pale yellow oil is separated from the aqueous distillate [37]. The antimicrobial activity of Melaleuca may be mediated by interaction with and disruption of bacterial plasma membranes [36], whilst the anti-inflammatory activity may be attributed by the suppression of reactive oxygen species in monocytes and neutrophils [39,40].
Manuka (Leptospernum scoparium) is a bushy shrub that has deep green fragrant leaves that bears small white to pink flowers distributed throughout New Zealand in widely varying climates, altitudes and population densities [41]. The tree sheds its bark in long papery strips and has been traditionally used to treat many ailments [42]. It is touted as an antibacterial, antiseptic, antifungal and anti-inflammatory agent [43]. The active constituent of Manuka oil is thought to be beta-triketone [44,45].
The purpose of this study was to evaluate the mechanical and morphological behavior alterations of the maxillofacial prosthetic elastomer during longevity studies due to plant-based antimicrobial solutions and contaminated with staphylococcus epidermidis. The plant-based antimicrobial solutions from extensive search, and, to the best of the knowledge of the authors, have not previously been used as a cleansing agent for maxillofacial prostheses material. The null hypothesis was that the usage of plant-based antimicrobial solution in a longevity study would not affect the mechanical properties (elongation, tensile strength, tear strength and Shore A hardness) of the maxillofacial silicone elastomer.

2. Results

2.1. Mechanical Testing

A summary of the line plots of the mechanical parameters with standard deviation (SD) depicted by error bars are shown in Figure 1a–d.
Regression Analyses: Furthermore, a linear regression analysis for each of the mechanical parameters with their respective predictors at the specific time periods. Table 1 reports adjusted R2, R2 and F statistics from the regression analyses results run. The results from the regression analysis for the mechanical parameters of hardness, elongation and tear strength revealed that the varying time periods variables were statistically significant as summarized F (6, 41) = 10.082, p < 0.0005, R2 = 0.537; F (6, 10) = 8.876, p < 0.002, R2 = 0.842 and F (6, 10) = 3.459, p < 0.002, R2 = 0.675, respectively. However, regression results from tensile strength was not statistically significant across the varying time periods; F (6, 10) = 2.457, p > 0.524, R2 = 0.596.
ANOVA Analyses: The null hypothesis was tested using a mixed design ANOVA repeated measures, where the independent variables were the conditioned silicone samples and test conditions (procedure time). The dependent variables were the Shore A hardness and tensile properties (tear strength, elongation percentage at break; tensile strength). The independent variables were the procedural times. Significant differences detected by the ANOVA (p < 0.05) prompted pairwise comparisons with Bonferroni post hoc tests.
In comparing the effect of the conditioned samples with time periods, we conducted a six (conditioned sample: Silicone (control sample) (Si); silicone autoclaved (SiAu); silicone with tea tree oil (SiTTO); silicone with Manuka oil (SiMO); silicone with tea tree oil, staphylococcus epidermidis and autoclaved (SiTTOBAu) and silicone with Manuka oil, staphylococcus epidermidis and autoclaved (SiMOBAu)) ×10 (Time: 24 h, 28 days, 3 months, 6 months, 9 months, 12 months) repeated measures ANOVA.
Mauchly’s test of sphericity, which determines the differences between conditions are equal indicated that the assumption of sphericity had been violated for the within subjects’ effect χ2 (14) = 25.605, p = 0.034 (elongation); χ2 (14) = 74.746, p < 0.05 (hardness). Therefore, the degrees of freedom were corrected using Greenhouse-Geisser estimates ε = 0.483 (elongation) and ε = 0.504 for the main effect of hardness tensile strength respectively. Meanwhile, tensile and tear strength parameter did not indicate any violation of the sphericity condition effect χ2 (14) = 19.320, p = 0.166 and χ2 (14) = 13.897, p = 0.474, respectively.
Furthermore, the mixed design ANOVA repeated measures with a Greenhouse-Geisser correction as seen in Table 2. Furthermore, the mixed design ANOVA repeated measures with a Greenhouse-Geisser correction for the Shore A hardness and elongation of the samples were statistically significantly different thus (F (2.893, 121.517) = 12.720, p < 0.0005, R2 = 0.537, η2 = 0.232) and (F (2.414, 26.559) = 3.909, p = 0.026, R2 = 0.842, η2 = 0.262), respectively. Hence, the results suggest that there was a statistical significance on the main effects of Shore A hardness and elongation at break with the procedure times.
The interaction of the procedure time with the hardness samples was statistically significant (F (25, 121.517) = 11.080, p < 0.0001, η2 = 0.569), indicating the effect of the procedure time on the hardness of the samples differed. Post hoc tests using Bonferroni correction revealed a statistically significant reduction by an average of 1.723 (p < 0.003) between day 1 and month 1 (p < 0.003); 2.098 (p < 0.0001) between day 1 and 12 months, 1.298 (p < 0.0001) between month 6 and 1 months, 1.502 (p < 0.001) between month 1 and 9 months, 1.169 (p = 0.014) between month 9 and 3 months and then reduced additionally by 1.877 between month 9 to 12 (p < 0.0001).
The interaction of the procedure time with the elongation samples were not statistically significant F (12.072, 26.559) = 1.187, p = 0.292, η2 = 0.350), indicating that the main effect of the procedure time on the elongation of the test sample did not differ over the procedure time. Bonferroni post hoc tests revealed statistically significant differences of a mean increment of 113.211 (month 1 to 3; p < 0.009); 103.557 (month 1 and 12 months; p < 0.027) and further reduced by-86.118 (month 9 to 12; p < 0.015).
Additionally, for the tensile strength of samples, the difference between the means were significantly different (F (5, 55) = 10.093, p < 0.0005, η2 = 0.478), respectively. A Bonferroni post hoc test revealed a significant difference in the means of the tensile strength samples 0.607 (day 1 and 3 month; p < 0.10); 0.756 (day 1 and month 4; p < 0.010); 0.996 (day 1 and 12 months; p < 0.0001), one month and 12 months an increase of 0.592 (p < 0.007), month 9 and 12 a reduction in −0.756 (p < 0.10). However, the interaction effect between the tensile strength samples and the procedure time (F (25, 55) = 1.593, p = 0.076, η2 = 0.420) revealed non-statistical significance. Post hoc Bonferroni results disclosed a statistical significance between procedure time 1 month and samples (Si and SiMOBAu) mean reduction of 0.978 (p < 0.039); month 12 and sample (Si and SiAu) mean reduction of 1.244 (p < 0.010); month 12 and sample (SiAu and SiTTO, SiAu and SiMO, respectively) mean increment of 0.980 (p < 0.047) and 1.099 (p < 0.021), respectively.
Additionally, for tear strength, the difference between the means was not statistically significant different at (F (5, 25) = 1.049, p = 0.399, η2 = 0.087), respectively. Interaction effects of the procedure time with tear strength (F (25, 55) = 0.601, p = 0.917, η2 = 0.215) were also not statistically significant.
Furthermore, examination into the conditioned silicone hardness and tensile strength samples showed that the control Si and SiAu hardness samples differed significantly over the varying time periods, which could be due to the high temperature of the autoclaving process influencing the crosslinking of the SiAu hardness test samples. In addition, the SiTTO and SiMO hardness samples were also significantly different, even though the antimicrobial solutions utilised in the study were from the same family, whilst the tensile strength samples were significantly the same. Likewise, the SiMOBAu and SiTTOBAu hardness and tensile strength samples were significantly the same, which indicates the presence of the staphylococcus epidermidis and the usage of the antimicrobial solutions caused the same effect in the samples, though initially with the SiTTO and SiMO hardness samples they differed significantly over the time period.

2.2. Morphological Testing

Visual observations revealed a brownish yellowish colour for the SiTTO; SiMO, SiTTOBAu and SiMOBAu samples. This indicates that the antimicrobial solutions tea tree and Manuka; the presence of antimicrobial compounds; or even the autoclaving process was having an effect on the test samples.
Silicone elastomer test samples were examined by SEM after the visual observation for any visible changes. Using a 120, 1 K, 5 K and 10 K revealed deterioration of the of the prostheses material for the procedure duration. The higher magnification revealed the extent of deterioration of the prosthesis material. Figure 2 displays changes over the day 1; 6-month and 12-month periods at a magnification of 5 K.

3. Discussion

For the mechanical parameters hardness and elongation, we accept the hypothesis that variance differences over the time period were significant. However, for tear and tensile strength, we reject the null hypothesis that, at the varying time periods, were not significantly different.
Overall, the general pattern of the hardness of the samples increases slightly within the 1- to 28-day period and then levels out across all test samples up until month 9, then slightly increases until month 12. Furthermore, the tensile strength of the samples decreases for all samples from day 1 to month 6 and then increases slightly from month 6 to month 9 and further decreases slightly until month 12. Additionally, the elongation at break of the samples increases from day 1 to day 28 and then decreases from 28 days to three months and then increases between months 3 to 6 and then commences to decrease across all samples. In addition, the tear strength of the samples decreases sharply from day 1 to 28 days and then almost levels out from 28 days to six months and then gradually starts to increase between months 6 to 9 and then increases for all samples except for Si samples, which decreases. Overall, as the hardness of the samples increases over the procedure duration, the tensile strength seemed to decrease whilst the elongation at break and tear strength revealed no definite pattern over that same procedure duration.
Overall, statistically significant differences were observed in hardness test samples as well as the procedure duration. This may have resulted from the resistance of the silicone samples to compression during the testing.
Accelerated aging has been shown to have an effect on the aging of silicone properties, mostly because photo-oxidation and hydrolysis of silicone are the main degradation reactions and they occur after the material has been exposed to sunlight, air, humidity and temperature [26]. Similar studies have attributed an increment or decrement of hardness to surface alterations and not water absorption [30]; the decomposition of the cleaning solution into carbon monoxide, carbon dioxide and sulfur dioxide, which could lead to either a hardening or a softening of materials [46]. Similarly, an increment and decrement in hardness of silicone after disinfection has been attributed to continuous polymerization of the silicone; the polymerization process can usually be slowed by a reaction between the disinfection products, absorption of the disinfection solution that could lead to a porous structure [47]. Another study [48] indicated significant differences in hardness, percentage elongation, tensile strength and tear strength in three maxillofacial silicone materials (M511, Z004 and M511) with thixotropic agents added. The low molecular weight polymer chains of M511 are considered the weakest points in the cross-linked structure, hence leading to low tensile and tear strength [48]. However, a low cross-link density between polymer chains allows more elasticity in tension and reduces rigidity and hardness [48], which might explain the results obtained in the current study.
Photomicrographs from this study indicated that over time the surface of the maxillofacial prostheses developed ridges, which could be due to the antimicrobial solutions as well as dead bacteria on the surface of the test samples. The ridges observed on the surface could in effect serve as a source in which bacteria grow.
Only one type of maxillofacial silicone material and only a single type of bacteria (staphylococcus epidermidis) were utilized for this study. Additionally, other well-known factors such as sweat, mucosa, saliva and many others that have been found to cause biofilm formation can be incorporated into future research design. Furthermore, maxillofacial prosthesis materials from different manufacturers or a variety of different bacteria might cause the results observed in this study to vary. Hence, proprietary information of the components of the silicone from the different manufacturers makes it arduous to assess the transferability of the results obtained. Furthermore, studies in determining the effects of other fungi or bacteria such as Candida spp., Enterobacter cloacae, Staphylococcus aureus, Serratia marcesens, Pseudomonas aeruginosa and many others might need to be performed in the future to gain better insight of its effect on prosthesis materials. In addition, surface analyses such as abrasive wear, surface roughness, micro-indentation and many others need to be performed to prove the extent and rate of degradation of the surface of the maxillofacial material. Additionally, longitudinal color change and conditional factors such as water intake and porosity can also be evaluated to fully understand the degradation process.

4. Materials and Methods

All raw materials; manufacturers and batch/lot numbers utilized in this research are listed in Table 3. The mechanical properties, Shore A hardness, tensile strength, percentage elongation at break and tear strength were investigated with antimicrobial solution and disinfected with staphylococcus epidermidis.

4.1. Sample Preparation

4.1.1. Silicone Elastomer

Maxillofacial silicone elastomer was mixed manually for 10 min in a ratio of 10:1 (base: catalyst) according to the manufacturer’s instructions. The silicone elastomer utilized in this study uses a cross-linking system via an addition reaction. The silicone base contains vinyl terminated polydimethylsiloxanes, surface treated silica fillers and a Platinum complex as catalysts [48]. The cross-linker (part B) contained a hydrogen siloxane polymer. The silicone was then poured into polycarbonate plates and its surface was smoothened until it was level throughout the plate. Air bubble elimination was achieved by using a pressure pot or storing in a refrigerator to slow the curing process. The samples were then put into an oven at 70 °C for 60 to 80 min. After polymerization, the silicone was taken out of the polycarbonate plates and stored. Test samples were then cut out from these silicone sheets. All test specimens were visually inspected to ensure that they were free of any defects and specimens with air bubbles were discarded.

4.1.2. Antimicrobial Disinfectant

The staphylococcus epidermidis was utilized for this study, since it is part of the human skin flora as well as its availability and accessibility.

4.1.3. Bacterial Preparation

Nutrient broth and agar solutions were prepared following the manufacturer’s instruction. The nutrient agar and broth solutions were then autoclaved (Astell Scientific Portaclave, Size 4) prior to usage at 121 °C for 15 min. After autoclaving, the nutrient agar was stored in a water bath at 60 °C, whilst the nutrient broth is inoculated with a loop full of staphylococcus epidermidis. This solution was then left in the incubator at 37 °C overnight (24 h) for the growth of the staphylococcus epidermidis before usage. Bacterial cultures of staphylococcus epidermidis were made from stock cultures of American Type Culture Collection ATCC 14990/NCIMB 12721 (Manassas, VA, USA). These were grown in nutrient broth (Oxoid CM001), inoculated and incubated at 37 °C overnight. Nutrient agar (LABM) plates were then prepared and seeded with 1 mL of the overnight culture.

4.1.4. Antimicrobial Disinfectant Minimum Inhibitory Concentration

Antimicrobials utilized in this study (tea tree and Manuka oil) were chosen based on documented and/or anecdotal antimicrobial effects. Furthermore, a thorough search revealed that these oils had not previously been used as a cleanser for maxillofacial prostheses.
Varying concentrations of both antimicrobial solutions were prepared in an increasing two-fold dilution series concentration volumes as shown in Table 4 in determining the minimum inhibitory concentration over 24, 48 and 72 h, respectively, in an infected staphylococcus epidermidis agar plate. The minimum mean concentration volumes at which a distinct clear zone is observed was noted. The concentration volume of antimicrobial solutions (tear tree and Manuka oil) that inhibited the growth of the staphylococcus epidermidis bacteria cultures are shown in Table 5.

4.1.5. Conditioning of Samples for Mechanical Testing

Standardized cut test pieces were conditioned for mechanical testing. The conditioning applied are as follows: a. silicone (control sample) (Si); b. silicone autoclaved (Si/Au); c. silicone with Tea tree oil (SiTTO); d. silicone with Manuka oil (SiMO); e. silicone with tea tree oil, staphylococcus epidermidis and autoclaved (SiTTOBAu) and f. silicone with Manuka oil, staphylococcus epidermidis and autoclaved (SiMOBAu). Conditioning with tea tree and Manuka oil (SiTTO and SiMO) was done by placing the silicone test samples in a petri dish filled with distilled water and the minimum inhibitory concentration of the antimicrobial solution, while conditioning of (SiTTOBAu) and (SiMOBAu) was done with the test samples put in a solution of staphylococcus epidermidis for 24 h and afterwards placed in a petri dish filled with distilled water and the minimum inhibitory concentration of the antimicrobial solutions.

4.1.6. Conditioning Time Periods with Antimicrobial Solution

The simulated times utilized were 1 day; 28 days; 3 months; 6 months; 9 months and 12 months, respectively. Simulated times from 1 day to 28 days were followed accordingly whilst simulated times commencing from 3 months to 12 months followed a procedure duration as similarly performed elsewhere [30]. Procedure duration was adopted to reduce the risk of any infection or contamination. All conditioned samples infected with staphylococcus epidermidis were autoclaved after contact with antimicrobial solutions. The procedure duration time series utilised is shown in Table 6.

4.2. Mechanical (Quantitative) Testing

4.2.1. Hardness

Hardness specimens (25 mm by 25 mm by 6 mm) were cut manually into the test samples. Three hardness specimens were prepared for each test criteria. The specimens were tested according to ASTM D 2240 [49]. A Shore A durometer (Durometer Type M, Shore Instrument and Mfg Co., Inc., New York, NY, USA) was utilised. For each specimen, eight (8) readings were taken with 6 mm distance maintained between readings and of the edges of test specimen.

4.2.2. Tensile Strength

Three type 2 dumbbell shaped tensile tests specimens were fabricated as per ISO specification number 37, type 1 [50]. Tensile grips were installed on a universal testing machine (Lloyd LR50K Tensometer Test Machine, Lloyds Instruments Ltd., West Sussex, UK) with a separation of 20 mm between them. The tensile strength tests were performed at 50 mm/min crosshead speed with a 50 N load cell. Prior to testing, the thickness of each specimen was measured using a thickness gauge at the centre and the end of each test specimen. The average thicknesses were then used for cross-sectional area calculations. The tensile strength (Ts) and elongation percentage at break (EP) is then calculated automatically using Equations (1) and (2):
Ts = F b w t ,
EP = L b L o L o × 100 ,
where Fb is the force recorded at break (N), wt is the width of the narrow portion of the specimen (mm), t is the thickness of the test length, Lo is initial test length and Lb is the test length at break (mm).

4.2.3. Tear Strength Test

Trouser shaped tear strength test specimens were fabricated 100 mm × 15 mm × 2 mm and tested according to the ISO 34-1 using a (Lloyd LR50K Tensometer Test Machine, Lloyds Instruments Ltd., West Sussex, UK) [51]. A cut in the test specimen was made at the centre of the width of the test piece (40 mm long). The test specimen trouser legs were inserted symmetrically and in axial alignment with the direction of the pull in each grip. The depth of insertion was 30 mm ensuring the specimens was held adequately firmly. Specimens were tested at a strain rate of 100 mm/min. The tear strength is expressed in kN/m and calculated by Equation (3), where Ts is tear strength, F is force at break and d is the thickness of the test sample:
Ts = F d .

4.3. Morphology Testing

4.3.1. Visual Observation

Visual observation was observed for each of the samples after the conditioning as well as after testing of the samples. The observations were noted and recorded.

4.3.2. Scanning Electron Microscopy Testing

The scanning electron microscope (SEM) instrument images the surface of the sample by scanning it with a high-energy beam of electrons. The SEM was used to examine any structural and changes on the surface of the test samples.

4.3.3. Characterization of Test Samples

Scanning electron microscopic (SEM) examination was performed using an analytical scanning electron microscope (FIB–SEM Nova 600 NanoLab, FEI Company, Hillsboro, OR, USA) to monitor any changes within the surface of the silicone elastomer matrix as well as within due to microbial infection and the usage of the plant based disinfectants.

4.3.4. Sample Preparation for Scanning

Thin cross sections of the silicone sample were prepared and mounted rigidly on specimen holders. The silicone elastomer is non-conductive, hence the specimens were coated with an ultrathin coating of gold, by sputtering and the images were taken using a low voltage SEM at 150 kV.

4.4. Data Analysis

Descriptive statistics were generated from all quantitative data specifically means; standard deviations and variances using SPSS for windows software (IBM SPSS 24.0, Inc., Chicago, IL, USA). Furthermore, data from the quantitative studies of the experimental groups were collected and compared to the control group using a repeated measure analysis of variance (ANOVA) for tensile strength, percentage elongation at break, tear strength and Shore A hardness [52] as well as a regression analysis.
For qualitative data obtained, visual colour changes observed during the conditioning and testing are noted. Images obtained from the SEM are also observed to note any changes in the structure and surface of the samples under testing.

5. Conclusions

Within the limitations of this study, Shore A hardness and elongation properties revealed changes after disinfection as compared to tear and tensile strength mechanical properties, which did not. In addition, surface changes and colour within the test samples revealed that perhaps microbial infections as well as disinfection have an effect on the maxillofacial silicone during the long-term period.

Author Contributions

S.T., R.J.B. and S.J.M. initiated the concept and design. R.J.B. and S.J.M. have contributed as advisors. S.T. conducted the experiments. S.J.M., R.J.B. and S.T. contributed to the analysis and interpretation of data, as well as co-writing the manuscript. All authors read and approved the final manuscript.

Funding

This research was funded by Engineering and Physical Sciences Research Council (EPSRC) grant number [EP/ M027341/1] Tackling Antimicrobial Resistance: An Interdisciplinary Approach.

Acknowledgments

This work was supported by the Schlumberger Foundation, Faculty for the future grant for ST’s doctoral studies. The authors thank Keith Yendall of the Loughborough Materials and Characterisation Centre, Institute of Polymer Technology and Materials Engineering, Loughborough University, United Kingdom and Tim Coles (Chemical Engineering, Loughborough University).

Conflicts of Interest

The authors declare no conflict of interest.

Abbreviations

ANOVAAnalysis of variance
ATCCAmerican Type Culture Collection
Fbthe force recorded at break
°Cdegrees Celsius
SDStandard deviation
SEMScanning electron microscopy
Sisilicone (control sample)
SiAusilicone autoclaved
SiMOsilicone with Manuka oil
SiMOBAusilicone with manuka oil, staphylococcus epidermidis and autoclaved
SiTTOsilicone with tea tree oil
SiTTOBAusilicone with tea tree oil, staphylococcus epidermidis and autoclaved
UVUltraviolet

References

  1. Pigno, M.A.; Goldschmidt, M.C.; Lemon, J.C. The efficacy of antifungal agents incorporated into a facial prosthetic silicone elastomer. J. Prosthet. Dent. 1994, 71, 295–300. [Google Scholar] [CrossRef]
  2. Micheline Dos Santos, D.; Goiato, M.C.; Moreno, A.; Pesqueira, A.A.; Dekon, S.F.D.C.; Guiotti, A.M. Effect of addition of pigments and opacifier on the hardness, absorption, solubility and surface degradation of facial silicone after artificial ageing. Polym. Degrad. Stab. 2012, 97, 1249–1253. [Google Scholar] [CrossRef]
  3. Hatamleh, M.M.; Watts, D.C. Bonding of maxillofacial silicone elastomers to an acrylic substrate. Dent. Mater. 2010, 26, 387–395. [Google Scholar] [CrossRef] [PubMed]
  4. Al-Harbi, F.A.; Ayad, N.M.; Saber, M.A.; Arrejaie, A.S.; Morgano, S.M. Mechanical behavior and color change of facial prosthetic elastomers after outdoor weathering in a hot and humid climate. J. Prosthet. Dent. 2015, 113, 146–151. [Google Scholar] [CrossRef] [PubMed]
  5. Han, Y.; Zhao, Y.; Xie, C.; Powers, J.M.; Kiat-Amnuay, S. Color stability of pigmented maxillofacial silicone elastomer: Effects of nano-oxides as opacifiers. J. Dent. 2010, 38 (Suppl. 2), e100–e105. [Google Scholar] [CrossRef] [PubMed]
  6. Han, Y.; Kiat-amnuay, S.; Powers, J.M.; Zhao, Y. Effect of nano-oxide concentration on the mechanical properties of a maxillofacial silicone elastomer. J. Prosthet. Dent. 2008, 100, 465–473. [Google Scholar] [CrossRef]
  7. Guiotti, A.M.; Cunha, B.G.; Paulini, M.B.; Goiato, M.C.; dos Santos, D.M.; Duque, C.; Caiaffa, K.S.; Brandini, D.A.; Narciso de Oliveira, D.T.; Brizzotti, N.S.; et al. Antimicrobial activity of conventional and plant-extract disinfectant solutions on microbial biofilms on a maxillofacial polymer surface. J. Prosthet. Dent. 2016, 116, 136–143. [Google Scholar] [CrossRef] [PubMed]
  8. Ariani, N.; Vissink, A.; van Oort, R.P.; Kusdhany, L.; Djais, A.; Rahardjo, T.B.W.; van der Mei, H.C.; Krom, B.P. Microbial biofilms on facial prostheses. Biofouling 2012, 28, 583–591. [Google Scholar] [CrossRef] [PubMed]
  9. Karakoca, S.; Aydin, C.; Yilmaz, H.; Bal, B.T. Retrospective study of treatment outcomes with implant-retained extraoral prostheses: Survival rates and prosthetic complications. J. Prosthet. Dent. 2010, 103, 118–126. [Google Scholar] [CrossRef]
  10. Visser, A.; Raghoebar, D.M.D.G.M.; Oort, R.P.; Van Vissink, A. Fate of Implant-Retained Craniofacial Prostheses: Life Span and Aftercare. Int. J. Oral Maxillofac. Implants 2008, 23, 89–98. [Google Scholar] [PubMed]
  11. Eleni, P.N.; Katsavou, I.; Krokida, M.K.; Polyzois, G.L.; Gettleman, L. Mechanical behavior of facial prosthetic elastomers after outdoor weathering. Dent. Mater. 2009, 25, 1493–1502. [Google Scholar] [CrossRef] [PubMed]
  12. Mitra, A.; Choudhary, S.; Garg, H.; Jagadeesh, H.G. Maxillofacial prosthetic materials—An inclination towards silicones. J. Clin. Diagn. Res. 2014, 8, ZE08–ZE13. [Google Scholar] [CrossRef] [PubMed]
  13. Thomas, K.F. Prosthetic Rehabilitation; Quintessence Publishing Co., Ltd.: London, UK, 1994. [Google Scholar]
  14. Eggbeer, D. The Computer Aided Design and Fabrication of Facial Prostheses. Ph.D. Thesis, University of Wales Institute, Cardiff, Wales, UK, 2008. [Google Scholar]
  15. Eleni, P.N.; Krokida, M.K.; Polyzois, G.L. The effect of artificial accelerated weathering on the mechanical properties of maxillofacial polymers PDMS and CPE. Biomed. Mater. 2009, 4, 035001. [Google Scholar] [CrossRef] [PubMed]
  16. Eleni, P.N.; Krokida, M.K.; Polyzois, G.L.; Charitidis, C.A.; Koumoulos, E.P.; Tsikourkitoudi, V.P.; Ziomas, I. Mechanical behaviour of a poydimethylsiloxane elastomer after outdoor weathering in two different weathering locations. Polym. Degrad. Stab. 2011, 96, 470–476. [Google Scholar] [CrossRef]
  17. Leow, E.L.; Pereira, B.P.; Kour, A.K.; Pho, R.W. Lifelikeness in multilayered digital prostheses. Prosthet. Orthot. Int. 1997, 21, 40–51. [Google Scholar] [PubMed]
  18. Vojdani, M.; Zibaei, M.; Aar, K.; Zomorodian, K.; Ma, R.; Boshehri, S. In-vitro Study of the Effect of Clotrimazole Incorporation into Silicone Soft Liner on Fungal Colonization. J. Dent. 2009, 9, 19–23. [Google Scholar]
  19. Ploux, L.; Beckendorff, S.; Nardin, M.; Neunlist, S. Quantitative and morphological analysis of biofilm formation on self-assembled monolayers. Colloids Surf. B Biointerfaces 2007, 57, 174–181. [Google Scholar] [CrossRef] [PubMed]
  20. Ariani, N.; Visser, A.; Teulings, M.R.I.M.; Dijk, M.; Rahardjo, T.B.W.; Vissink, A.; van der Mei, H.C. Efficacy of cleansing agents in killing microorganisms in mixed species biofilms present on silicone facial prostheses—An in vitro study. Clin. Oral Investig. 2015, 19, 2285–2293. [Google Scholar] [CrossRef] [PubMed]
  21. Ariani, N. Microbial Biofilms on Silicone Facial Prostheses. Ph.D. Thesis, University of Groningen, Groningen, The Netherlands, 2015. [Google Scholar]
  22. Beumer, J.; Curtis, T.A.; Firtell, D.N. Maxillofacial Rehabilitation. J. Prosthet. Dent. 1979, 333–364. [Google Scholar] [CrossRef]
  23. Pesqueira, A.A.; Goiato, M.C.; dos Santos, D.M.; Haddad, M.F.; do Prado Ribeiro, P.; Coelho Sinhoreti, M.A.; Marçal Mazza Sundefeld, M.L. Effect of Disinfection and Accelerated Aging on Color Stability of Colorless and Pigmented Facial Silicone. J. Prosthodont. 2011, 20, 305–309. [Google Scholar] [CrossRef] [PubMed]
  24. Goiato, M.C.; Pesqueira, A.A.; Ramos da Silva, C.; Filho, H.G.; Micheline dos Santos, D. Patient satisfaction with maxillofacial prosthesis. Literature review. J. Plast. Reconstr. Aesthet. Surg. 2009, 62, 175–180. [Google Scholar] [CrossRef] [PubMed]
  25. Reisberg, D.J.; Habakuk, S.W. Hygiene procedures for implant-retained facial prostheses. J. Prosthet. Dent. 1995, 74, 499–502. [Google Scholar] [CrossRef]
  26. Goiato, M.C.; Pesqueira, A.A.; Moreno, A.; Dos Santos, D.M.; Haddad, M.F.; Bannwart, L.C. Effects of pigment, disinfection, and accelerated aging on the hardness and deterioration of a facial silicone elastomer. Polym. Degrad. Stab. 2012, 97, 1577–1580. [Google Scholar] [CrossRef]
  27. Markt, J.C.; Lemon, J.C. Extraoral maxillofacial prosthetic rehabilitation at the MD Anderson Cancer Center: A survey of patient attitudes and opinions. J. Prosthet. Dent. 2001, 85, 608–613. [Google Scholar] [CrossRef] [PubMed]
  28. Goiato, M.C.; Haddad, M.F.; Sinhoreti, M.A.C.; dos Santos, D.M.; Pesqueira, A.A.; Moreno, A. Influence of opacifiers on dimensional stability and detail reproduction of maxillofacial silicone elastomer. Biomed. Eng. 2010, 9, 85. [Google Scholar] [CrossRef] [PubMed]
  29. Áurea, M.; Ferreira, F.; Pereira-cenci, T. Efficacy of denture cleansers on denture liners contaminated with Candida species. Clin. Oral Investig. 2009, 13, 237–242. [Google Scholar]
  30. Eleni, P.N.; Perivoliotis, D.; Dragatogiannis, D.A.; Krokida, M.K.; Polyzois, G.L.; Charitidis, C.A.; Ziomas, I.; Gettleman, L. Tensile and microindentation properties of maxillofacial elastomers after different disinfecting procedures. J. Mech. Behav. Biomed. Mater. 2013, 28, 147–155. [Google Scholar] [CrossRef] [PubMed]
  31. Hatamleh, M.M.; Watts, D.C. Effect of Extraoral Aging Conditions on Color Stability of Maxillofacial Silicone Elastomer. J. Prosthodont. 2010, 19, 536–543. [Google Scholar] [CrossRef] [PubMed]
  32. Peralta, S.L.; Carvalho, P.H.A.; van de Sande, F.H.; Pereira, C.M.P.; Piva, E.; Lund, R.G. Self-etching dental adhesive containing a natural essential oil: Anti-biofouling performance and mechanical properties. Biofouling 2013, 29, 345–355. [Google Scholar] [CrossRef] [PubMed]
  33. Gyawali, R.; Ibrahim, S.A. Natural products as antimicrobial agents. Food Control 2014, 46, 412–429. [Google Scholar] [CrossRef]
  34. Chen, X.; Zhang, H. Temperature and humidity effect on aging of silicone rubbers as sealing materials for proton exchange membrane fuel cell applications. Appl. Therm. Eng. 2016, 104, 472–478. [Google Scholar]
  35. Cowan, M.M. Plant products as antimicrobial agents. Clin. Microbiol. Rev. 1999, 12, 564–582. [Google Scholar] [PubMed]
  36. Cox, S.D.; Mann, C.M.; Markham, J.L.; Bell, H.C.; Gustafson, J.E.; Warmington, J.R.; Wyllie, S.G. The mode of antimicrobial action of the essential oil of Melaleuca alternifolia (Tea tree oil). J. Appl. Microbiol. 2000, 88, 170–175. [Google Scholar] [CrossRef] [PubMed]
  37. Carson, C.F.; Hammer, K.A.; Riley, T.V.; Carson, C.F.; Hammer, K.A.; Riley, T.V. Melaleuca alternifolia (Tea Tree) Oil: A Review of Antimicrobial and Other Medicinal Properties. Clin. Microbiol. Rev. 2006, 19, 50–62. [Google Scholar] [CrossRef] [PubMed]
  38. Kwieciński, J.; Eick, S.; Wójcik, K. Effects of tea tree (Melaleuca alternifolia) oil on Staphylococcus aureus in biofilms and stationary growth phase. Int. J. Antimicrob. Agents 2009, 33, 343–347. [Google Scholar] [CrossRef] [PubMed]
  39. Hart, P.H.; Brand, C.; Carson, C.F.; Riley, T.V.; Prager, R.H.; Finlay-Jones, J.J. Terpinen-4-ol, the main component of the essential oil of Melaleuca alternifolia (tea tree oil), suppresses inflammatory mediator production by activated human monocytes. Inflamm. Res. 2000, 49, 619–626. [Google Scholar] [CrossRef] [PubMed]
  40. Brand, C.; Ferrante, A.; Prager, R.H.; Riley, T.V.; Carson, C.F.; Finlay-Jones, J.J.; Hart, P.H. The water-soluble components of the essential oil of Melaleuca alternifolia (tea tree oil) suppress the production of superoxide by human monocytes, but not neutrophils, activated in vitro. Inflamm. Res. 2001, 50, 213–219. [Google Scholar] [CrossRef] [PubMed]
  41. Chen, C.C.; Yan, S.H.; Yen, M.Y.; Wu, P.F.; Liao, W.T.; Huang, T.S.; Wen, Z.H.; David Wang, H.M. Investigations of kanuka and manuka essential oils for in vitro treatment of disease and cellular inflammation caused by infectious microorganisms. J. Microbiol. Immunol. Infect. 2016, 49, 104–111. [Google Scholar] [CrossRef] [PubMed]
  42. Van Vuuren, S.F.; Docrat, Y.; Kamatou, G.P.P.; Viljoen, A.M. Essential oil composition and antimicrobial interactions of understudied tea tree species. S. Afr. J. Bot. 2014, 92, 7–14. [Google Scholar] [CrossRef]
  43. Lauten, J.D.; Boyd, L.; Hanson, M.B.; Lillie, D.; Gullion, C.; Madden, T.E. A clinical study: Melaleuca, Manuka, Calendula and green tea mouth rinse. Phyther. Res. 2005, 19, 951–957. [Google Scholar] [CrossRef] [PubMed]
  44. Christoph, F.; Kaulfers, P.-M.; Stahl-Biskup, E. In vitro Evaluation of the Antibacterial Activity of β-Triketones Admixed to Melaleuca Oils. Planta Med. 2001, 67, 768–771. [Google Scholar] [CrossRef] [PubMed]
  45. Douglas, M.H.; Van Klink, J.W.; Smallfield, B.M.; Perry, N.B.; Anderson, R.E.; Johnstone, P.; Weavers, R.T. Essential oils from New Zealand manuka: Triketone and other chemotypes of Leptospermum scoparium. Phytochemistry 2004, 65, 1255–1264. [Google Scholar] [CrossRef] [PubMed]
  46. Hatamleh, M.M.; Haylock, C.; Watson, J.; Watts, D.C. Maxillofacial prosthetic rehabilitation in the UK: A survey of maxillofacial prosthetists’ and technologists’ attitudes and opinions. Int. J. Oral Maxillofac. Surg. 2010, 39, 1186–1192. [Google Scholar] [CrossRef] [PubMed]
  47. Goiato, M.C.; Haddad, M.F.; Santos, D.M.; Pesqueira, A.A.; Moreno, A. Hardness evaluation of prosthetic silicones containing opacifiers following chemical disinfection and accelerated aging. Braz. Oral Res. 2010, 24, 303–308. [Google Scholar] [CrossRef] [PubMed]
  48. Bibars, A.R.M.; Al-Hourani, Z.; Khader, Y.; Waters, M. Effect of thixotropic agents as additives on the mechanical properties of maxillofacial silicone elastomers. J. Prosthet. Dent. 2018, 119, 671–675. [Google Scholar] [CrossRef] [PubMed]
  49. Standard Test Method for Rubber Property—Durometer Hardness; ASTM D2240-15; ASTM International: West Conshohocken, PA, USA, 2012.
  50. Rubber, Vulcanized or Thermoplastic—Determination of Tensile Stress-Strain Properties; ISO 37; International Organization for Standardization: Geneva, Switzerland, 2017.
  51. Rubber, Vulcanized or Thermoplastic—Determination of Tear Strength—Part 1; ISO 34-1; International Organization for Standardization: Geneva, Switzerland, 2010.
  52. Zayed, S.M.; Alshimy, A.M.; Fahmy, A.E. Effect of surface treated silicon dioxide nanoparticles on some mechanical properties of maxillofacial silicone elastomer. Int. J. Biomater. 2014, 2014, 14–15. [Google Scholar] [CrossRef] [PubMed]
Figure 1. (a) line plot displaying means; standard deviation error bars and offset (+5—SiAu; +10—SiTTO; +15—SiMO; +20—SiTTOBAu; +25—SiMOBAu) for Shore A hardness samples. (b) line plot displaying means; standard deviation error bars and offset (+5 MPa—SiAu; +10 MPa —SiTTO; +15 MPa —SiMO; +20 MPa —SiTTOBAu; +25 MPa —SiMOBAu) for tensile strength samples; (c) line plot displaying means; standard deviation error bars and offset (+100%—SiAu; +200%—SiTTO; +300%—SiMO; +400%—SiTTOBAu; +500%—SiMOBAu) for elongation at break samples; (d) line plots displaying means; standard deviation error bars and offset (+5 kN/m —SiAu; +10 kN/m —SiTTO; +15 kN/m —SiMO; +20 kN/m —SiTTOBAu; +25 kN/m —SiMOBAu) for tear strength samples.
Figure 1. (a) line plot displaying means; standard deviation error bars and offset (+5—SiAu; +10—SiTTO; +15—SiMO; +20—SiTTOBAu; +25—SiMOBAu) for Shore A hardness samples. (b) line plot displaying means; standard deviation error bars and offset (+5 MPa—SiAu; +10 MPa —SiTTO; +15 MPa —SiMO; +20 MPa —SiTTOBAu; +25 MPa —SiMOBAu) for tensile strength samples; (c) line plot displaying means; standard deviation error bars and offset (+100%—SiAu; +200%—SiTTO; +300%—SiMO; +400%—SiTTOBAu; +500%—SiMOBAu) for elongation at break samples; (d) line plots displaying means; standard deviation error bars and offset (+5 kN/m —SiAu; +10 kN/m —SiTTO; +15 kN/m —SiMO; +20 kN/m —SiTTOBAu; +25 kN/m —SiMOBAu) for tear strength samples.
Materials 11 00925 g001aMaterials 11 00925 g001b
Figure 2. Photomicrograph of test samples at magnification of 5 K. (a) SiTTOBAu at Day 1 (b) SiTTOBAu at 6 months (c) SiTTOBAu at 12 months (d) SiMOBAu at Day 1 (e) SiMOBAu at 6 months and (f) SiMOBAu at 12 months.
Figure 2. Photomicrograph of test samples at magnification of 5 K. (a) SiTTOBAu at Day 1 (b) SiTTOBAu at 6 months (c) SiTTOBAu at 12 months (d) SiMOBAu at Day 1 (e) SiMOBAu at 6 months and (f) SiMOBAu at 12 months.
Materials 11 00925 g002
Table 1. Regression summary of mechanical parameters.
Table 1. Regression summary of mechanical parameters.
Mechanical ParametersRR2Adjusted R SquareFdf2Sig. F Change
Hardness0.7720.5960.53710.082410.000
Tensile0.7720.5960.3532.457100.100
Tear Strength0.8210.6750.4803.459100.041
Elongation0.9180.8420.7478.876100.002
df = degree of freedom.
Table 2. ANOVA table for mechanical parameters in this study.
Table 2. ANOVA table for mechanical parameters in this study.
Mechanical ParametersSourcedfSSMSFp
HardnessTime (within)2.893183.10563.28712.720.000
Time × Silicone (within)14.466797.50955.12911.0800.000
TensileTime (within)59.4841.89710.0930.000
Time × Silicone (within)257.4840.2991.5930.076
Elongation at breakTime (within)1.00249,062.363249,062.3633.9090.074
Time × Silicone (within)12.072378,233.86931,330.2601.1870.341
Tear StrengthTime (within)57,620,067.6081,524,012.5211.0490.389
Time × Silicone (within)2521,850,848.090874,033.9240.6010.917
df = degree of freedom; SS = sum of squares; MS = mean square.
Table 3. Materials utilized in this research study.
Table 3. Materials utilized in this research study.
MaterialsManufacturerBatch/Lot Number
M511 Platinum Silicone Part ATechnovent, Bridgend, Wales, UKB17D/B17AH
M511 Platinum Silicone Part BTechnovent, Bridgend, Wales, UKB16C/B17D
Manuka OilEssential Oils Direct, Oldham, UK8583/9124
Tea Tree OilEssential Oils Direct, Oldham, UK9100
Table 4. Varying concentrations of antimicrobial solutions.
Table 4. Varying concentrations of antimicrobial solutions.
Volume UsedVolume/Volume Percent Solution (v/v) %
%0.050.10.20.41.02.04.08.016.0
Tea TreeµL1530601203006001200--
Manuka--2410204080160
Table 5. Varying concentrations of antimicrobial solutions.
Table 5. Varying concentrations of antimicrobial solutions.
Test AgentStaphylococcus Epidermidis
Tea Tree Oil0.2% (v/v)
Manuka Oil0.4% (v/v)
Table 6. Simulated time periods utilised for conditioning test samples.
Table 6. Simulated time periods utilised for conditioning test samples.
Procedure Duration Utilised for Conditioning Samples
Simulated Time (m—months; d—days)12 m9 m6 m3 m28 d1 d
Procedure Time (hours)3022.5157.52.50.083

Share and Cite

MDPI and ACS Style

Tetteh, S.; Bibb, R.J.; Martin, S.J. Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Maxillofacial Silicone Elastomer. Materials 2018, 11, 925. https://doi.org/10.3390/ma11060925

AMA Style

Tetteh S, Bibb RJ, Martin SJ. Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Maxillofacial Silicone Elastomer. Materials. 2018; 11(6):925. https://doi.org/10.3390/ma11060925

Chicago/Turabian Style

Tetteh, Sophia, Richard J. Bibb, and Simon J. Martin. 2018. "Mechanical and Morphological Effect of Plant Based Antimicrobial Solutions on Maxillofacial Silicone Elastomer" Materials 11, no. 6: 925. https://doi.org/10.3390/ma11060925

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop